Subassembly Names Disappear on Copy, Move or Mirror

Do your Subassembly names disappear whenever you use the subassembly commands “Copy to”, “Move to”, or “Mirror”?

image

image

After the jump learn how to resolve this issue.

The issue lies with the subassembly naming template.  I don’t know if others out there in blog land knew this but using “<[Subassembly Local Name]>” is no good.

image

To fix the issue change your naming template to use “<[Macro Short Name]>” (see below).

image

The same name is provided but now when you copy, move, or mirror the names don’t disappear.  🙂

image

Hope this helps…

Comments are closed.